Kwang Air Shower

Use And Maintenance Of Air Shower

Home > Maintenance > Specification For Use Of Air Shower

Specification For Use Of Air Shower

  • 2023-12-06
  • View 19

Specifications for using the air shower room:


1. Before entering the air shower room: after changing clothes and shoes, check whether the air shower room is idle through the window of the air shower room and indicator lights; The door lock of the air shower room is damaged. After the work of the air shower room is completed, the indoor personnel leave, and they can enter about two seconds after the door is automatically closed;


2. After entering the air shower room: directly pass the photoelectric sensor, and the shower starts. Please lift your hands in the room and then rotate 360 degrees to shower;


3. Finished showering: Two seconds after the fan in the air shower room stops running, open the door and leave the air shower room. During the air shower process, the front and rear doors of the air shower room are locked. Do not open them forcibly, so as not to damage the interlock device and door lock. In case of emergency, please press the emergency stop switch, and the air shower room will stop working. When entering and exiting the door, open and pass at will. During the idle period, the entry and exit doors of the air shower are in an electronic interlocking state. Only one side of the entrance and exit door can be opened, please do not open it by force.


The performance stability of the air shower room is not only the selection of good products, but also the maintenance and maintenance. The automatic air shower room has been strictly tested when the product leaves the factory, and various operating parameters have been determined during the installation and commissioning process. Therefore, we usually only need to operate and maintain according to the instruction manual. If there is a fault, it is best to eliminate it through the manufacturer.


1. According to the cleanliness of the environment, replace the filter regularly (the initial effect is generally 1-3 months, and the initial effect can be cleaned; the high-efficiency is generally 6-12 months).


2. Regularly (generally once every two months) use a dust particle counter to measure the cleanliness of the cleanliness area or the cleanliness of the cleanliness that is purified by this product. Whether the high efficiency is invalid, etc.) If the high efficiency filter has failed, it should be replaced with a new high efficiency filter.


3. When replacing the high-efficiency filter and the primary filter, the machine should be shut down.


4. The sticky dust mat inside and outside the air shower needs to be replaced in time, once a day before employees enter the workshop, about four times a day.


Air shower use steps air shower use specifications



Use And Maintenance Of Air Shower


cache
Processed in 0.008376 Second.