Kwang Air Shower

Air Shower Industry Classification

Home > Industry Classification > Air shower For Biological Pharmacy
Air shower For Biological Pharmacy

Air shower For Biological Pharmacy

In this article, we will discuss how an air shower can help to maintain sterility in biological pharmacy.

Maintaining sterility is crucial in biological pharmacy to ensure the safety and efficacy of pharmaceutical products. In this article, we will discuss how an air shower can help to maintain sterility in biological pharmacy. 


Introduction

Biological pharmacy deal with sensitive and delicate products that require sterile conditions during the manufacturing and packaging process. Contamination by microorganisms or other foreign particles can compromise the safety and effectiveness of these products. Therefore, it is important to have proper measures in place to maintain sterility. One of the effective ways to achieve this is by using an air shower.


What is an Air Shower?

An air shower is an enclosed area designed to blow high-velocity clean air over an individual or object to remove surface particles. It is typically a small room with two doors, and the person or object to be decontaminated enters through one door and exits through the other. The air shower is equipped with high-efficiency particulate air (HEPA) filters that remove 99.99% of particles as small as 0.3 microns.


How does an Air shower For Biological Pharmacy Work?

An air shower works by blowing high-velocity clean air over a person or object to remove surface particles. When the person or object enters the air shower, the HEPA filters remove the surface particles from their clothes or surface. The high-velocity air is then blown over the person or object to further remove any remaining particles. The air is then recirculated through the HEPA filters to ensure that the air in the air shower remains clean.


Benefits of Using an Air Shower in Biological Pharmacy

Using an air shower in biological pharmacy has several benefits:

Reduces the risk of contamination by removing surface particles from people and objects entering the cleanroom.

Maintains the integrity of the cleanroom environment by preventing contamination from outside sources.

Helps to ensure compliance with regulatory standards and guidelines for pharmaceutical manufacturing and packaging.

Increases the safety and efficacy of pharmaceutical products by minimizing the risk of contamination.


Types of Air Showers For Biological Pharmacy

There are two main types of air showers: personnel air showers and goods air showers.

Personnel Air Showers

Personnel air showers are designed to decontaminate people entering or exiting the cleanroom. They are typically used in areas where personnel movement is high. Personnel air showers are equipped with HEPA filters and powerful blowers that remove surface particles from the person's clothes and skin.


Goods Air Showers

Goods air showers are designed to decontaminate objects or materials entering or exiting the cleanroom. They are typically used in areas where goods movement is high. Goods air showers are equipped with HEPA filters and powerful blowers that remove surface particles from the objects or materials.


Factors to Consider When Choosing an Air Shower For Biological Pharmacy

When choosing an air shower, there are several factors to consider to ensure that it meets the specific requirements of the biological pharmacy:

Airflow Velocity

The airflow velocity of the air shower should be high enough to remove surface particles from people or objects, but not so high that it disrupts the cleanroom environment.


HEPA Filter Efficiency

The HEPA filter efficiency should be at least 99.99% for removing particles as small as 0.3 microns. This ensures that the air shower is effective in removing particles that may contain microorganisms.


Noise Level

The noise level of the air shower should be low enough to ensure that it does not cause distractions or interfere with the work environment.


Size and Design

The size and design of the air shower should be appropriate for the number of personnel or objects that will be entering or exiting the cleanroom. It should also be designed to prevent the escape of contaminated air into the cleanroom environment.


Maintenance of Air Showers For Biological Pharmacy

To ensure the effectiveness of the air shower in maintaining sterility, regular maintenance is necessary. This includes replacing the HEPA filters at regular intervals, cleaning the air shower regularly, and ensuring that the airflow velocity and noise level are within the recommended levels.


Conclusion

Using an air shower is an effective way to maintain sterility in biological pharmacy. It helps to remove surface particles from people and objects entering the cleanroom, reducing the risk of contamination. There are different types of air showers available, and it is important to consider factors such as airflow velocity, HEPA filter efficiency, noise level, size, and design when choosing an air shower. Regular maintenance is also necessary to ensure the effectiveness of the air shower in maintaining sterility.


FAQs

Can an air shower completely eliminate the risk of contamination in a biological pharmacy?

No, an air shower cannot completely eliminate the risk of contamination, but it can significantly reduce the risk by removing surface particles from people and objects entering the cleanroom.


How often should the HEPA filters be replaced in an air shower?

The HEPA filters should be replaced at least once a year, or more frequently if the air shower is being used frequently.


Can an air shower be used in other industries besides pharmaceuticals?

Yes, air showers can be used in other industries such as electronics manufacturing, aerospace, and food processing.


Are there any safety concerns associated with using an air shower?

No, air showers are safe to use as long as they are maintained properly and used according to the manufacturer's instructions.


How long does it take to decontaminate a person or object using an air shower?

The decontamination process typically takes between 20-30 seconds, but this can vary depending on the size of the air shower and the airflow velocity.